STL31N65M5
Electrical characteristics
Symbol
Parameter
td (v)
tr (v)
tf (i)
tc(off)
Voltage delay time
Voltage rise time
Current fall time
Crossing time
Table 6. Switching times
Test conditions
VDD = 400 V, ID = 14 A,
RG = 4.7 Ω, VGS = 10 V
(see Figure 20)
Min. Typ. Max. Unit
- 46 - ns
-
8
- ns
- 8.5 - ns
- 11 - ns
Table 7. Source drain diode
Symbol
Parameter
Test conditions
Min. Typ. Max. Unit
ISD (1) Source-drain current
-
ISDM (1),(2) Source-drain current (pulsed)
-
VSD (3) Forward on voltage
ISD = 15 A, VGS = 0
-
trr
Qrr
IRRM
Reverse recovery time
Reverse recovery charge
Reverse recovery current
-
ISD = 15 A, di/dt= 100 A/µs
-
VDD = 100 V (see Figure 17)
-
trr
Qrr
IRRM
Reverse recovery time
Reverse recovery charge
Reverse recovery current
ISD = 15 A, di/dt= 100 A/µs
-
VDD = 100 V, Tj = 150 °C
-
(see Figure 17)
-
1. The value is rated according to Rthj-case and limited by package.
2. Pulse width limited by safe operating area
3. Pulsed: pulse duration = 300 µs, duty cycle 1.5%
15 A
60 A
1.5 V
290
ns
4
µC
27
A
340
ns
5
µC
29
A
DocID025459 Rev 1
5/17
17