M62255FP
Table 4 Amp Select
D3
D2
D1
D0
State
—
0
0
0
select Output of Charge Current Detect Amp
—
0
0
1
select Input of Battery Voltage Detect Amp
—
0
1
0
select Output of Battery Voltage Detect Amp
—
0
1
1
select Output of Discharge Current Detect Amp
—
1
0
0
select Output of A/D reference Voltage
Note: Output of Battery Voltage Detect Amp is selected at RESET
Table 5 A/D Input Select
D3
D2
D1
—
—
0
—
—
0
—
—
1
—
—
1
Note: IN1 is selected at RESET
D0
State
0
select IN1
1
select IN2
0
select IN3
1
select IN4
Table 6 A/D Reference Voltage Select
D3
D2
D1
0
0
0
0
0
0
0
0
1
0
0
1
0
1
0
0
1
0
0
1
1
0
1
1
1
0
0
1
0
0
1
0
1
1
0
1
1
1
0
1
1
0
1
1
1
1
1
1
Note: 2.50 V is selected at RESET
D0
State
0
select 5.0 V
1
select 4.69 V
0
select 4.38 V
1
select 4.06 V
0
select 3.75 V
1
select 3.44 V
0
select 3.13 V
1
select 2.81 V
0
select 2.50 V
1
select 2.19 V
0
select 1.88 V
1
select 1.56 V
0
select 1.25 V
1
select 0.94 V
0
select 0.63 V
1
select 0.31 V
REJ03F0245-0200 Rev.2.00 Sep 14, 2007
Page 7 of 12