DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

L9935 데이터 시트보기 (PDF) - STMicroelectronics

부품명
상세내역
제조사
L9935
ST-Microelectronics
STMicroelectronics ST-Microelectronics
L9935 Datasheet PDF : 29 Pages
First Prev 21 22 23 24 25 26 27 28 29
L9935
Functional description
5.16
Application information
For driving a stepper motor we suggest to use the following codes. The columned ’SDO
correct’ shows the data returned at SDO in correct function. The columns presented under
’Error cases’ display the diagnosis bits if errors are detected.
Examples of control sequences.
Table 10. Full step mode control sequences and diagnosis response
SDI
SDO
correct
Error cases and SDObit7, bit6
A B A1 A2 B1 B2 A1 A2 B1 B2 therm. therm.
(1) (1) (1) (1)
OOS S S S S S S S
PPHHHHHHHH
shut down
-
-
E
N
E
N
O
R
O
R
O
R
O
R
O
R
O
R
O
R
O
R
alarm
(reset
operating
TTTTTTTT
codes)
bit 76543210 76543210 76
VS VS VS VS GND GND GND GND
76 76 76 76 76 76 76 76 76 76
76543210
XX111111
SDO present last data or 11111111 in case prev. state was standby
XX011011 11111111 11 11 11 11 11 11 11 11 11 11 00
XX010011 11011011 11 11 11 01 11 01 10 11 10 11 00
XX010010 11010011 01 11 01 01 11 01 01 10 10 11 00
XX011010 11010010 11 01 01 11 01 01 11 10 01 10 00
XX011011 11011010 01 11 01 01 01 11 10 01 11 10 00
XX010011 11011011 11 01 11 01 01 01 10 11 10 01 00
XX010010 11010011 01 11 01 01 11 01 01 10 10 11 00
XX011010 11010010 11 01 01 11 01 01 11 10 01 10 00
00111111
00111111
00111111
00111111
00111111
00111111
00111111
00111111
1. Motor resistance approximately 10and VS = 12V. So a short to ground only is detected on one branch of the bridge.
Lower resistivity of the motor may lead to detection of short to ground on both branches of the bridge leading to code 10 on
all steps.
These sequences are intended to give the user a good starting point for his software
development. Besides these two there are further possibilities how to implement control
sequences for this device (other currents, quarters step etc.).
Double errors: Double errors will create composite codes by an AND operation between
columns of the same dominance. Open and short to VS are the least dominant error codes.
(first 6 error code columns). Short to ground is the second dominant error code. detection of
short to gnd will overwrite error codes of the least dominant kind (open, short to VS).
Temperature pre alarm and thermal shut down are the most dominant error codes. Thermal
pre alarm returns error code 00 but the device still is working and returns the appropriate
operation code (bits 0..5).
Thermal shut down returns error code 00 and turns off the device. The opcode returned
corresponds the action eventually performed (bit 0..5 become 1).
For example open bridge A and simultaneously open bridge B will lead to error code 01 by
performing an AND operation between the two corresponding columns.
Doc ID 5198 Rev 10
23/29

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]