MITSUBISHI <DIGITAL ASSP>
M66290AGP/FP
USB DEVICE CONTROLLER
(2-8) Interrupt Status Register 3 (Address : 1Eh)
D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
EPB_EMP_OVR[5:0]
Bit
Bit
Name
15 to 6 Reserved
Name
Write/Read "0"
Function
Reset
W/R
H/W S/W USB
When factors below are occurred to each endpoint, the bit which
corresponds to the number of endpoint, changes to "1".
5 to 0
EPB_
EMP_
OVR
[5:0]
Endpoint5-0 buffer
empty/size error
interrupt
1. If the transfer direction is IN
In each endpoint, when transmission completed of all data which stored
in buffer, c
By this interrupt, if endpoint is set to double buffer, it can be known that
transmission of all data of buffer is completed.
And also by this interrupt, it can be known that transmission of EP0 is
completed.
2. If the direction is OUT
In each endpoint, when received data which exceeds the maximum
packet size in data packet receive, the bit which corresponds to the
number of endpoint changes to "1".
W/R 00h 00h -
When "0" is written, status flag is cleared.
When "1" is written, status flag is not cleared.
19