MAX6816/MAX6817/
MAX6818
±15kV ESD-Protected, Single/Dual/Octal,
CMOS Switch Debouncers
tDP
IN1
OUT1
IN2
OUT2
CH
MAX6818 ONLY
Figure 2. Input Characteristics
20V
IN 0V
(20V/div)
-20V
4V
OUT
(2V/div)
0V
20ms/div
Figure 3. Switch Input ±25V Fault Tolerance
Robust Switch Inputs
The switch inputs on the MAX6816–MAX6818 have
overvoltage-clamping diodes to protect against damaging
fault conditions. Switch input voltage scan safely swing
±25V to ground (Figure 3). Proprietary ESD-protection
structures protect against high ESD encountered in
harsh industrial environments, membrane keypads, and
portable applications. They are designed to withstand
±15kV per the IEC 1000-4-2 Air-Gap Discharge Test and
±8kV per the IEC 1000-4-2 Contact Discharge Test.
Since there are 63k(typical) pullup resistors
connected to each input, driving an input to -25V draws
approximately 0.5mA (up to 4mA for eight inputs) from
the VCC supply. Driving an input to +25V will cause
approximately 0.32mA of current (up to 2.6mA for eight
EN
tEN
1/2 VCC
1/2 VCC
OUT1–OUT8
OUT1–OUT8
CH
tPE
1/2
VCCOUT
NORMALLY
LOW
tPE 1/2 VCC OUT NORMALLY
HIGH
tPC
1/2 VCC
tPD
VOL + 0.5V
VOH - 0.5V
tPD
Figure 4. MAX6818 μP Interface Timing Diagram
+VCC
SW1
IN1
IN8
SW8
0.1µF
MAX6818
EN
CH
OUT1
OUT8
+VCC
I/O
µP
IRQ
D0
D7
Figure 5. MAX6818 Typical μP Interfacing Circuit
inputs) to flow back into the VCC supply. If the total system
VCC supply current is less than the current flowing back
into the VCC supply, VCC will rise above normal levels.
In some low-current systems, a zener diode on VCC may
be required.
±15kV ESD Protection
As with all Maxim devices, ESD-protection structures are
incorporated on all pins to protect against electrostatic dis-
charges encountered during handling and assembly. The
MAX6816–MAX6818 have extra protection against static
electricity. Maxim’s engineers have developed state-of-
the-art structures to protect against ESD of ±15kV at the
switch inputs without damage. The ESD structures with-
stand high ESD in all states: normal operation, shutdown,
and powered down. After an ESD event, the MAX6816–
MAX6818 keep working without latchup, whereas other
solutions can latch and must be powered down to
remove latchup.