ERRATA
11/20/97
1. In default mode, the video data changes on the falling edge of PCLK instead of on the rising edge. We
recommand inverting the PCLK pin polarity by setting MCTL(1) so the video data can still be latched
on the falling edge of PCLK. All the pclk timing parameters is applied to inverted PCLK.
2. OV5017 default active HREF window width has one extra pixel, 385 instead of 384, the back porch
blanking is one less, that is:
tHACT = 385, tHB = 32.
2/14/98
3. A glitch ( width 1/2 ~ 10 PCLKS) in HREF appears between VSYNC and the first valid HREF if pro-
grammed FRCTL(5:0) >= 9.
4. Intensity of lines (32,33,256,257) may be different from the rest of image if programmed FRCTL(5:0)=
4,5,9~11,13~15,17~22,24~63.