MeshConnect™ EM357 Module
Wave Soldering
If a wave soldering process is required on the host boards due to the presence of leaded components, only a
single wave soldering process is encouraged.
Hand Soldering
Hand soldering is possible. When using a soldering iron, follow IPC recommendations (reference document IPC-
7711).
Rework
The MeshConnect Module can be unsoldered from the host board. Use of a hot air rework tool should be pro-
grammable and the solder joint and module should not exceed the maximum peak reflow temperature of 250ºC.
D Caution
E If temperature ramps exceed the reflow temperature profile, module and component damage may occur due to
thermal shock. Avoid overheating.
D Warning
N N Never attempt a rework on the module itself, (e.g. replacing individual components). Such actions will
terminate warranty coverage.
E IG Additional Grounding
Attempts to improve module or system grounding by soldering braids, wires, or cables onto the module RF shield
M cover is done at the customer's own risk. The numerous ground pins at the module perimeter should be sufficient
S for optimum immunity to external RF interference.
M E AGENCY CERTIFICATIONS
O D FCC Compliance Statement (Part 15.19) Section 7.15 of RSS-GEN
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
C 1. This device may not cause harmful interference.
E W 2. This device must accept any interference received, including interference that may cause undesired
operation.
E Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.
R L'exploitation est autorisée aux deux conditions suivantes:
N 1. l'appareil ne doit pas produire de brouillage, et
T 2. l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
O R susceptible d'en compromettre le fonctionnement.
Warning (Part 15.21)
N FO Changes or modifications not expressly approved by CEL could void the user's authority to operate the equipment.
20 cm Separation Distance
To comply with FCC/IC RF exposure limits for general population/uncontrolled exposure, the antenna(s) used for
this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not
be co-located or operating in conjunction with any other antenna or transmitter.
OEM Responsibility to the FCC Rules and Regulations
The MeshConnect Module has been certified per FCC Part 15 Rules for integration into products without further
testing or certification. To fulfill the FCC Certification requirements, the OEM of the MeshConnect Module must
Page 13