FUNCTIONAL DEVICE OPERATION
OPERATIONAL MODES
Table 12. Analog Channel
Bits 43210
Analog Channel Select
00000
00001
00010
00011
00100
00101
00110
00111
01000
01001
01010
01011
01100
01101
01110
01111
10000
10001
10010
10011
10100
10101
10110
No Input Selected
SG0
SG1
SG2
SG3
SG4
SG5
SG6
SG7
SG8
SG9
SG10
SG11
SG12
SG13
SP0
SP1
SP2
SP3
SP4
SP5
SP6
SP7
CALIBRATION OF TIMERS
In cases where an accurate time base is required, the user
may calibrate the internal timers using the calibration
command (refer to Table 13). After the 33975 device
receives the calibration command, the device expects 512 s
logic [0] calibration pulse on the CS pin. The pulse is used to
calibrate the internal clock. No other SPI pins should
transition during this 512 s calibration pulse. Because the
oscillator frequency changes with temperature, calibration is
required for an accurate time base. Calibrating the timers has
no affect on the quiescent current measurement. The
calibration command simply makes the time base more
accurate. The calibration command may be used to update
the device on a periodic basis. All reset conditions clear the
calibration register and places the device in the uncalibrated
state.
Table 13. Calibration Command
Calibration Command
Command Bits
23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
0 0 0 0 1 0 1 1XXXXXXXXXXXXXXXX
RESET
The reset command resets all registers to Power-ON Reset
(POR) state. Refer to Table , page 20, for POR states or the
paragraph entitled Power-ON Reset (POR) on page 16 of
this datasheet.