92HD001
2-CHANNEL HIGH DEFINITION AUDIO CODEC
PC AUDIO
5. Ratio of Full Scale signal to idle channel noise output is measured “A weighted” over a 20 Hz to a 20 KHz
bandwidth. (AES17-1991 Idle Channel Noise or EIAJ CP-307 Signal-to-noise Ratio).
6. Peak-to-Peak Ripple over Passband meets ± 0.25dB limits, 48 KHz Sample Frequency.
7. Stop Band rejection determines filter requirements. Out-of-Band rejection determines audible noise.
8. The integrated Out-of-Band noise generated by the DAC process, during normal PCM audio playback, over a
bandwidth 28.8 to 100 KHz, with respect to a 1 Vrms DAC output.
IDT™ 2-CHANNEL HIGH DEFINITION AUDIO CODEC
16
IDT CONFIDENTIAL
92HD001
V 1.1 01/08