DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

LA76835 데이터 시트보기 (PDF) - SANYO -> Panasonic

부품명
상세내역
제조사
LA76835 Datasheet PDF : 50 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
Continued from preceding page.
Parameter
Symbol
R-Y/B-Y
RB
Demodulation
output ratio
R-Y/B-Y
Demodulation
output ratio
G-Y/B-Y
Demodulation
angle R-Y/B-Y
GB
ANGRB1
Demodulation
angle R-Y/B-Y
Control 1
Demodulation
angle R-Y/B-Y
Control 2
ANGRB2
ANGRB3
LA76835NM
Test point
18
19
20
Input signal
YIN: L77
C-1:
No signal
YIN: 0 IRE
C-3
Test method
Input a signal to YIN and adjust DAC in R and B
drives so that the Y output levels at pins 18 and 20
become as close to the level at 19 as possible. (*1)
After that, input 0 IRE to YIN and C-3 to CIN.
Measure BOUT output amplitude Vb and ROUT
output amplitude Vr and calculate RB=Vr/Vb.
Bus conditions
Color: 1000000
Adjustment value in
B and R drives: *1
C-3
19
C-1
20
18
Measure GOUT output amplitude Vg and
calculate GB = Vg/Vb.
For the R/B Drive, the adjustment value: *1
applies.
Measure each output level of the BOUT and ROUT
and calculate the angles of the B-Y axis and R-Y
axis.
ANGBR1 = (R-Y angle)-(B-Y angle)
Color: 1000000
Adjustment value in
B and R drives: *1
C-1
20
18
C-1
20
18
With R-Y/B-Y angle set at maximum, carry out the
same measurement as for ANGRB1.
ANGBR2 = (R-Y angle)-(B-Y angle)
R-Y/B-Y angle
1111
With R-Y/B-Y angle set at minimum, carry out the
same measurement as for ANGRB1.
ANGBR3 = (R-Y angle)-(B-Y angle)
Reset R-Y/B-Y angle to 1000.
R-Y/B-Y angle
0000
Demodulation
angle G-Y/B-Y
Demodulation
angle G-Y/B-Y control
Killer operating
point 2
ANGGB1
ANGGB2
KILL
Killer operating
point 4
KILL
Killer operating
point difference
Chroma VCO
free-running
frequency
APC pull-in range (+)
D_KILL
CVCOF
PLINP0
APC pull-in range (-)
PLINN0
Static phase error (+)
SPER_P
C-1
19
C-1
19
C-3
20
Measure each output level of the GOUT and
calculate the angle of the G-Y axis.
ANGBG1 = (G-Y angle)-(B-Y angle)
Measure each output level of the GOUT and
calculate the angle of the G-Y axis.
ANGBG2 = (G-Y angle)-(B-Y angle)
Reduce the input signal until the output level
becomes 50mVp-p or less. Measure the input level
at that moment.
G-Y_Angle: 1
Filter Sys: 1
C. Bypass: 0
ColorKillerope.: 2
C-3
20
Reduce the input signal until the output level
becomes 50mVp-p or less. Measure the input level
at that moment.
Filter Sys: 1
C. Bypass: 0
ColorKillerope.: 4
D_KILL = KILL-KILL4
CIN:
Measure oscillation frequency f.
44
No signal
CVCOF = f-3579545 (Hz)
C-1
20
C-1
20
C-1
20
Decrease the chroma fsc frequency from
3.579545MHz+1000Hz and measure the frequency
at which the VCO locks.
Increase the chroma fsc frequency from
3.579545MHz-1000Hz and measure the
frequency at which the VCO locks.
Set the fsc frequency to 3.579545MHz+200Hz,
measure the B-Y axis angle.
SPER_P = B-Y axis angle-TINCEN