M29W102BT, M29W102BB
Table 11. DC Characteristics
(TA = 0 to 70°C or –40 to 85°C)
Symbol
Parameter
ILI(1)
Input Leakage Current
ILR1 RP Leakage Current High
ILR2 RP Leakage Current Low
ILO
Output Leakage Current
ICC1 Supply Current (Read)
ICC2 Supply Current (Standby)
ICC3 (2) Supply Current (Program/Erase)
VIL
Input Low Voltage
VIH
Input High Voltage
VOL
Output Low Voltage
VOH Output High Voltage
VID
Identification Voltage
IID
Identification Current
VLKO (2)
Program/Erase Lockout Supply
Voltage
Note: 1. Excluding the RP input.
2. Sampled only, not 100% tested.
3. TA = 25°C, VCC = 3.3V
Test Condition
0V ≤ VIN ≤ VCC
RP = VCC
RP = VSS
0V ≤ VOUT ≤ VCC
E = VIL, G = VIH,
f = 6MHz
E = VCC ± 0.2V
Program/Erase
Controller active
IOL = 1.8mA
IOH = –100µA
A9 = VID
Min
–0.2
–0.5
0.7VCC
VCC – 0.4
11.5
1.8
Typ (3)
4
30
Max
Unit
±1
µA
±1
µA
–10
µA
±1
µA
10
mA
100
µA
20
mA
0.8
V
VCC + 0.3
V
0.45
V
V
12.5
V
100
µA
2.3
V
12/20