Philips Semiconductors
74AHC2G241; 74AHCT2G241
Dual buffer/line driver; 3-state
VI
PULSE
GENERATOR
VCC
VO
D.U.T.
RT
S1
RL =
1000 Ω
CL
mna232
VCC
open
GND
Test data is given in Table 13.
Definitions for test circuit:
CL = load capacitance including jig and probe capacitance (see Section 12 for the value).
RL = load resistance.
RT = Termination resistance should be equal to the output impedance Zo of the pulse
generator.
Fig 7. Load circuitry for switching times.
Table 13: Test data
Test
tPLH, tPHL
tPLZ, tPZL
tPHZ, tPZH
S1
open
VCC
GND
9397 750 12887
Product data sheet
Rev. 01 — 10 March 2004
© Koninklijke Philips Electronics N.V. 2004. All rights reserved.