DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ACS8520A 데이터 시트보기 (PDF) - Semtech Corporation

부품명
상세내역
제조사
ACS8520A Datasheet PDF : 150 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
ACS8520A SETS
ADVANCED COMMS & SENSING
FINAL
DATASHEET
considered to be locked when the phase loss/lock
z Averaged - (Reg. 40 Bit 7, cnfg_holdover_modes,
detectors (see “Phase Lock/Loss Detection” on page 21)
indicate that the DPLL has remained in phase lock
continuously for at least one second. When the
ACS8520A is in Locked mode, the output frequency and
phase tracks that of the selected input reference source.
Lost-phase Mode
Lost-phase mode is used whenever the phase loss/lock
detectors (see “Phase Lock/Loss Detection” on page 21)
indicate that the DPLL has lost phase lock. The DPLL will
still be trying to lock to the input clock reference, if it
exists. If the Leaky Bucket Accumulator calculates that
the anomaly is serious, the device disqualifies the
reference source. If the device spends more than 100
seconds in Lost-phase mode, the reference is disqualified
and a phase alarm is raised on it. If the reference is
disqualified, one of the following transitions takes place:
1. Go to Pre-locked2;
- If a known good stand-by source is available.
2. Go to Holdover;
- If no stand-by sources are available.
Holdover Mode
Holdover mode is the operating condition the device
enters when its currently selected input source becomes
invalid, and no other valid replacement source is
available. In this mode, the device resorts to using stored
auto_averaging: set High), or
z Instantaneous - (Reg. 40 Bit 7, cnfg_holdover_modes,
auto_averaging: set Low).
Averaged
In the Averaged mode, the frequency (as reported by
sts_current_DPLL_frequency, see Reg. 0C, 0D and 07) is
filtered internally using an Infinite Impulse Response
filter, which can be set to either:
z Fast - (Reg. 40 Bit 6, cnfg_holdover_modes,
fast_averaging: set High), giving a -3 dB filter
response point corresponding to a period of
approximately eight minutes, or
z Slow - (Reg. 40 Bit 6, cnfg_holdover_modes,
fast_averaging: set Low) giving a -3 dB filter response
point corresponding to a period of approximately 110
minutes.
Instantaneous
In Instantaneous mode, the DPLL freezes at the frequency
it was operating at the time of entering Holdover mode. It
does this by using only its internal DPLL integral path
value (as reported in Reg. 0C, 0D and 07) to determine
output frequency. The DPLL proportional path is not used
so that any recent phase disturbances have a minimal
effect on the Holdover frequency. The integral value used
can be viewed as a filtered version of the locked output
frequency over a short period of time. The period being in
inverse proportion to the DPLL bandwidth setting.
frequency data, acquired when the input reference source
was still valid, to control its output frequency.
In Holdover mode, the ACS8520A provides the timing and
synchronization signals to maintain the Network Element
but is not phase locked to any input reference source. Its
output frequency is determined by an averaged version of
the DPLL frequency when last in the Locked Mode.
Holdover can be configured to operate in either:
z Automatic mode
(Reg. 34 Bit 4, cnfg_input_mode: man_holdover set
Low), or
z Manual mode
(Reg. 34 Bit 4, cnfg_input_mode: man_holdover set
High).
Automatic Mode
In Automatic mode, the device can be configured to
operate using either:
Manual Mode
(Reg. 34 Bit 4, cnfg_input_mode, man_holdover set
High.) The Holdover frequency is determined by the value
in register cnfg_holdover_frequency (Reg. 3E, 3F, and
part of 40). This is a 19-bit signed number, with a LSB
resolution of 0.0003068 ppm, which gives an adjustment
range of ±80 ppm. This value can be derived from a
reading of register sts_current_DPLL_frequency (Reg. 0C,
0D and 07), which gives, in the same format, an indication
of the current output frequency deviation, which would be
read when the device is locked. If required, this value
could be read by external software and averaged over
time. The averaged value could then be fed to the
cnfg_holdover_frequency register, ready for setting the
averaged frequency value when the device enters
Holdover mode. The sts_current_DPLL_frequency value
is internally derived from the Digital Phase Locked Loop
(DPLL) integral path, which represents a short-term
average measure of the current frequency, depending on
the locked loop bandwidth (Reg. 67) selected.
Revision 1.00/September 2007© Semtech Corp.
Page 17
www.semtech.com