DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

7005 데이터 시트보기 (PDF) - Aeroflex Corporation

부품명
상세내역
제조사
7005 Datasheet PDF : 29 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
Pin #
1
42
40
49
51
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
56
90
60
Signal Name
CLOCK
DATA CHA
DATA CHA
DATA CHB
DATA CHB
DB0
DB1
DB2
DB3
DB4
DB5
DB6
DB7
DB8
DB9
DB10
DB11
DB12
DB13
DB14
DB15
DBCREQ
DS
DONE
Signal Description
6 MHz Master Clock.
DATA CHANNEL A. (BUS 0). This is the combined signals, RX
Data In and TX Data Out, that connect to the IN phase primary
terminal of the Bus Transformer.
DATA CHANNEL A. (BUS 0) This is the combined signals RX
Data In and TX Data Out, that connect to the OUT of phase
primary terminal of the Bus Transformer.
Same as DATA CHA, except for Channel B. (BUS 1).
Same as DATA CHA, except for Channel B. (BUS 1).
I/O DATA BUS. Data Bus for all SUBSYSTEM
READ and WRITE OPERATIONS.
16 BIT MODE
8 BIT MODE
DB0 = LSB
DB15 = MSB
DB0/DB8 = LSB
DB7/DB15 = MSB
When used in 8 BIT MODE the data bus must be
connected as follows:
DB0 TO DB8
DB1 TO DB9
DB2 TO DB10
DB3 TO DB11
DB4 TO DB12
DB5 TO DB13
DB6 TO DB14
DB7 TO DB15
Dynamic Bus Control Request. If OPERATION Register bit i5 is
set LOW, this line will pulse LOW in response to a Valid
Dynamic Bus Control Mode Command, indicating
ACCEPTANCE of Bus Control Function.
Device Select. This signal must be low before the interface can
be selected for an I/O Read or Write function. The I/O Data Bus
will remain tri-stated, no operations will be executed when this
signal is high.
Low Pulse Indicates an I/O Operation has completed
Table 11 – Pin Number Description (continued)
Aeroflex Circuit Technology
20
SCD7005 REV B 8/2/01 Plainview NY (516) 694-6700