Data Sheet
MEMORY MAP
READING THE MEMORY MAP REGISTER TABLE
Each row in the memory map register table has eight bit locations.
The memory map is roughly divided into four sections: the chip
configuration registers (Address 0x00 to Address 0x02); the transfer
register (Address 0xFF); the ADC functions registers, including
setup, control, and test (Address 0x08 to Address 0x20); and the
digital feature control registers (Address 0x3C and Address 0x3E).
The memory map register table (Table 13) documents the
default hexadecimal value for each hexadecimal address shown.
The Bit 7 (MSB) column is the start of the default hexadecimal
value given. For example, Address 0x14, the output mode
register, has a hexadecimal default value of 0x01. This means
that Bit 0 = 1 and the remaining bits are 0s. This setting is the
default output format value, which is twos complement. For
more information on this function and others, see the AN-877
Application Note, Interfacing to High Speed ADCs via SPI. This
document details the functions controlled by Register 0x00 to
Register 0x20. The remaining registers, Register 0x3C and
Register 0x3E, are documented in the Memory Map Register
Description section.
Open Locations
All address and bit locations that are not included in Table 13
are not currently supported for this device. Write 0s to unused
bits of a valid address location. Writing to these locations is
required only when part of an address location is open (for
example, Address 0x18). If the entire address location is open
(for example, Address 0x13), this address location should not be
written.
AD6672
Default Values
After the AD6672 is reset, critical registers are loaded with
default values. The default values for the registers are given in
the memory map register table (Table 13).
Logic Levels
An explanation of logic level terminology follows:
“Bit is set” is synonymous with “bit is set to Logic 1” or
“writing Logic 1 for the bit.”
“Clear a bit” is synonymous with “bit is set to Logic 0” or
“writing Logic 0 for the bit.”
Transfer Register Map
Address 0x08 to Address 0x20, as well as Address 0x3C and
Address 0x3E, are shadowed. Writes to these addresses do not
affect part operation until a transfer command is issued by
writing 0x01 to Address 0xFF, setting the transfer bit. This allows
these registers to be updated internally and simultaneously when
the transfer bit is set. The internal update takes place when the
transfer bit is set, and then the bit autoclears.