ADG1208/ADG1209
Parameter
CD, CS (On) ADG1208
CD, CS (On) ADG1209
POWER REQUIREMENTS
IDD
IDD
ISS
ISS
VDD/VSS
+25ºC
7
8
5
6
0.002
220
0.002
0.002
−40ºC to
+85ºC
−40ºC to
+125ºC
1.0
380
1.0
1.0
±5/±16.5
Unit
pF typ
pF max
pF typ
pF max
μA typ
μA max
μA typ
μA max
μA typ
μA max
μA typ
μA max
V min/max
Test Conditions/Comments
f = 1 MHz, VS = 0 V
f = 1 MHz, VS = 0 V
f = 1 MHz, VS = 0 V
f = 1 MHz, VS = 0 V
VDD = +16.5 V, VSS = −16.5 V
Digital inputs = 0 V or VDD
Digital inputs = 5 V
Digital inputs = 0 V or VDD
Digital inputs = 5 V
|VDD | = |VSS|
1 Temperature range is as follows: Y version: –40°C to +125°C.
2 Guaranteed by design, not subject to production test.
Rev. B | Page 4 of 20