DC and AC parameters
M24128-BW M24128-BR M24128-BF M24128-DF
8
DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device.
Symbol
VCC
TA
fC
Table 6. Operating conditions (voltage range W)
Parameter
Min.
Max.
Supply voltage
2.5
5.5
Ambient operating temperature
–40
85
Operating clock frequency
-
1
Unit
V
°C
MHz
Symbol
VCC
TA
fC
Table 7. Operating conditions (voltage range R)
Parameter
Min.
Max.
Supply voltage
Ambient operating temperature
1.8
5.5
–40
85
Operating clock frequency
-
1
Unit
V
°C
MHz
Table 8. Operating conditions (voltage range F)
Symbol
Parameter
Min.
Max.
Unit
VCC Supply voltage
1.6(1)
1.7
5.5
V
Ambient operating temperature: READ
-40
-40
85
TA
Ambient operating temperature: WRITE
0
-40
85
°C
fC
Operating clock frequency, VCC ≥ 1.6 V(1)
Operating clock frequency, VCC ≥ 1.7 V
-
-
400
kHz
1000
1. Only for devices identified with process letter T
Table 9. AC measurement conditions
Symbol
Parameter
Min.
Max.
Unit
Cbus Load capacitance
-
100
pF
-
SCL input rise/fall time, SDA input fall time
-
50
ns
-
Input levels
0.2 VCC to 0.8 VCC
V
-
Input and output timing reference levels
0.3 VCC to 0.7 VCC
V
24/46