6.1.13 MX1C Record Gain for Stereo ADC
Default: 8000h
Register 1Ch controls the record gain. Each step in bits 3:0 correspond to 1.5dB in increase/decrease in gain for the right
channel, allowing 16 levels of gain, from 0000 to 1111. Each step in bits 11:8 correspond to 1.5dB in increase/decrease in gain
for the left channel, allowing 16 levels of gain, from 0000 to 1111.
Bit
15
14:12
11:8
7:4
3:0
Type
R/W
R/W
R/W
Function
Mute Control 0: Normal 1: Mute (-dB)
Reserved
Left Record Gain Select (LRG[3:0]) in 1.5 dB steps
Reserved
Right Record Gain Select (RRG[3:0]) in 1.5 dB steps
For LRG/RRG:
0Fh +22.5dB
00h 0 dB (No Gain)
6.1.14 MX1E Record Gain for MIC ADC
Default: 8000h
Register 1Eh controls the record gain. Each step in bits 3:0 correspond to 1.5dB in increase/decrease in gain for the right
channel, allowing 16 levels of gain, from 0000 to 1111. Each step in bits 11:8 correspond to 1.5dB in increase/decrease in gain
for the left channel, allowing 16 levels of gain, from 0000 to 1111.
Bit Type
Function
15
R/W Mute Control 0: Normal 1: Mute (-dB)
14:12
Reserved
11:8 R/W Left Record Gain Select (LMRG[3:0]) in 1.5 dB steps
7:4
Reserved
3:0
R/W Right Record Gain Select (RMRG[3:0]) in 1.5 dB steps
For LRG/RRG:
0Fh +22.5dB
00h 0 dB (No Gain)
6.1.15 MX20 General Purpose Register
Default: 0000h
This register is used to control several functions. Bit 13 enables or disables 3D control. Bit 9 allows selection of mono output.
Bit 8 controls the MIC selector. Bit 7 enables loopback of the AD output to the DA input without involving the AC-Link,
allowing for full system performance measurements.
Bit
15:14
13
12:9
8
7
6:0
Type
R/W
R/W
R/W
Reserved, Read as 0
3D Control 1: On 0: Off
Reserved, Read as 0
MIC Select 0: MIC 1 1: MIC 2
AD to DA Loop-back Control 0: Disable
Reserved
Function
1: Enable