DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

AT49BV163D 데이터 시트보기 (PDF) - Atmel Corporation

부품명
상세내역
제조사
AT49BV163D Datasheet PDF : 27 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
AT49BV163D(T)
6. Command Definition Table
Command
Sequence
Bus
Cycles
1st Bus
Cycle
Addr Data
2nd Bus
Cycle
Addr Data
3rd Bus
Cycle
Addr Data
4th Bus
Cycle
Addr
Data
5th Bus
Cycle
Addr Data
6th Bus
Cycle
Addr Data
Read
Chip Erase
1
Addr DOUT
6
555
AA
AAA(2)
55
555
80
555
AA
AAA
55
555
10
Sector Erase
6
555
AA
AAA
55
555
80
555
AA
AAA
55
SA(3)(4)
30
Byte/Word Program
4
555
AA
AAA
55
555
A0
Addr
DIN
Enter Single Pulse
Program Mode
6
555
AA
AAA
55
555
80
555
AA
AAA
55
555
A0
Single Pulse
Byte/Word Program
1
Addr
DIN
Sector Lockdown
6
555
AA
AAA(2)
55
555
80
555
AA
AAA
55
SA(3)(4)
60
Erase/Program
Suspend
1
XXX
B0
Erase/Program
Resume
1
XXX
30
Product ID Entry
3
555
AA
AAA
55
555
90
Product ID Exit(5)
3
555
AA
AAA
55
555
F0(6)
Product ID Exit(5)
1
XXX
F0(6)
Program Protection
Register
4
555
AA
AAA
55
555
C0 Addr(7)
DIN
Lock Protection
Register - Block B
4
555
AA
AAA
55
555
C0
080
X0
Status of Block B
Protection
4
555
AA
AAA
55
555
90
80
DOUT(8)
Set Configuration
Register
4
555
AA
AAA
55
555
D0
XXX
00/01(9)
CFI Query(10)
1
X55
98
Notes: 1. The DATA FORMAT shown for each bus cycle is as follows; I/O7 - I/O0 (Hex). In word operation I/O15 - I/O8
are don’t care. The ADDRESS FORMAT shown for each bus cycle is as follows: A11 - A0 (Hex). Address A19 through A11
are don’t care in the word mode. Address A19 through A11 and A-1 are don’t care in the byte mode.
2. Since A11 is a Don’t Care, AAA can be replaced with 2AA.
3. SA = sector address. Any byte/word address within a sector can be used to designate the sector address (see pages 13 - 14
for details).
4. Once a sector is in the lockdown mode, data in the protected sector cannot be changed unless the chip is reset or power
cycled.
5. Either one of the Product ID Exit commands can be used.
6. Bytes of data other than F0 may be used to exit the Product ID mode. However, it is recommended that F0 be used.
7. Any address within the user programmable register region. Address locations are shown on “Protection Register Addressing
Table” on page 12.
8. If data bit D1 is “0”, block B is locked. If data bit D1 is “1”, block B can be reprogrammed.
9. The default state (after power-up) of the configuration register is “00”.
10. When accessing the data in the CFI table, the address format is A15 - A0 (Hex) in the word mode, A14 - A0 (Hex),
and A-1 = 0 in the byte mode.
11
3590A–FLASH–12/05

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]