Continued from preceding page.
Parameter
Total Gate Charge
Gate-to-Source Charge
Gate-to-Drain “Miller” Charge
Diode Forward Voltage
Package Dimensions
unit : mm
2168
2.9
543
1
0.95
2
0.4
0.4
CPH5614
Symbol
Qg
Qgs
Qgd
VSD
Conditions
VDS=50V, VGS=10V, ID=1A
VDS=50V, VGS=10V, ID=1A
VDS=50V, VGS=10V, ID=1A
IS=1A, VGS=0
Ratings
Unit
min
typ
max
6.5
nC
1.1
nC
1.1
nC
0.82
1.2
V
Electrical Connection
0.15
0.05
1 : Drain1
2 : Drain2
3 : Gate2
4 : Source
5 : Gate1
SANYO : CPH5
5
4
3
1
2
1 : Drain1
2 : Drain2
3 : Gate2
4 : Source
5 : Gate1
Top view
Switching Time Test Circuit
VIN
10V
0V
VIN
PW=10µs
D.C.≤1%
G
VDD=50V
ID=0.5A
RL=100Ω
D
VOUT
CPH5614
P.G
50Ω
S
ID -- VDS
1.0
0.8
0.6
0.4
2.5V
0.2
VGS=2.0V
0
0
0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6
Drain-to-Source Voltage, VDS -- V IT07445
ID -- VGS
2.0
VDS=10V
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
0
0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
Gate-to-Source Voltage, VGS -- V IT07446
No.8119-2/4