CXA1898Q
1. System control mode
Playback and recording equalizer
(1) Playback equalizer (120µs/70µs)
A-EQ (Pin 10)
L
H
DECK-AB
(serial data
D10 (Pin 25))
L
120µs
(A DECK)
70µs
(A DECK)
H According to B EQ control
B-EQ (Pin 11)
L
M/H
According to A EQ control
120µs
(B DECK)
70µs
(B DECK)
(2) Recording equalizer (Normal, CrO2, Metal)
B-EQ (Pin 11)
L
M
REC MODE Normal (Type I) CrO2 (Type II)
H
Metal (Type IV)
(3) Recording mute (Pin 12)
Rec Mute
Mute OFF
Control voltage GND ≤ VCL ≤ 0.5V
–7dB attenuation
2.0V
Mute ON
3.5V ≤ VCH ≤ VCC
Muting is achieved by varying the recording equalizer amplifier gain just like an electronic volume, according to
the DC voltage applied to the REC MUTE pin.
(4) FP CAL (Pin 4)
The standard resistor setting is 27kΩ, but when resistance value is larger, fo (Hz) is low, and when resistance
value is smaller, fo (Hz) is high.
(5) Gp Cal (Pin 5)
The standard resistor setting is 27kΩ, but when resistance value is larger, gain is larger, and when resistance
value is smaller, gain is smaller.