Command interface
M28W320FCT, M28W320FCB
Table 4. Commands(1)(2)
Bus Write Operations
Commands
1st Cycle
2nd Cycle
3rd Cycle
4th Cycle
5th Cycle
Op Add Data Op Add Data Op Add Data Op Add Data Op Add Data
Read Memory
Array
1+ Write X
Read Status
Register
1+ Write X
Read Electronic
Signature
1+ Write
X
FFh Read RA RD
70h Read X SRD
90h
Read
SA
(3)
IDh
Read CFI Query 1+ Write X
Erase
2 Write X
Program
2 Write X
Double Word
Program(4)
Quadruple Word
Program(5)
Clear Status
Register
3 Write X
5 Write X
1 Write X
98h Read QA QD
20h Write BA D0h
40h
or Write PA PD
10h
30h Write PA1 PD1 Write PA2 PD2
56h
(6)
Write PA1
PD1 Write
PA2 PD2 Write
PA3 PD3 Write
PA4 PD4
50h
Program/Erase
Suspend
1 Write X
Program/Erase
Resume
1 Write X
Block Lock
2 Write X
Block Unlock
2 Write X
Block Lock-Down 2 Write X
Protection
Register Program
2
Write
X
B0h
D0h
60h Write BA 01h
60h Write BA D0h
60h Write BA 2Fh
C0h Write PRA PRD
1. X = Don't Care, RA=Read Address, RD=Read Data, SRD=Status Register Data, ID=Identifier (Manufacture and Device
Code), QA=Query Address, QD=Query Data, BA=Block Address, PA=Program Address, PD=Program Data,
PRA=Protection Register Address, PRD=Protection Register Data.
2. 55h is reserved.
3. The signature addresses are listed in Table 5, Table 6 and Table 7.
4. Program Addresses 1 and 2 must be consecutive Addresses differing only for A0.
5. Program Addresses 1,2,3 and 4 must be consecutive Addresses differing only for A0 and A1.