M58LW032D
APPENDIX B. COMMON FLASH INTERFACE - CFI
The Common Flash Interface is a JEDEC ap-
proved, standardized data structure that can be
read from the Flash memory device. It allows a
system software to query the device to determine
various electrical and timing parameters, density
information and functions supported by the mem-
ory. The system can interface easily with the de-
vice, enabling the software to upgrade itself when
necessary.
When the CFI Query Command (RCFI) is issued
the device enters CFI Query mode and the data
structure is read from the memory. Tables 24, 25,
26, 27, 28 and 29 show the addresses used to re-
trieve the data.
Table 24. Query Structure Overview
Address
x16
x8(4)
Sub-section Name
Description
0000h
00h
Manufacturer Code
0001h
02h
Device Code
0010h
20h CFI Query Identification String
Command set ID and algorithm data offset
001Bh
36h System Interface Information
Device timing and voltage information
0027h
4Eh Device Geometry Definition
Flash memory layout
P(h)(1)
Primary Algorithm-specific Extended Additional information specific to the Primary
Query Table
Algorithm (optional)
A(h)(2)
Alternate Algorithm-specific Extended Additional information specific to the Alternate
Query Table
Algorithm (optional)
(SBA+02)h
Block Status Register
Block-related Information
Note: 1. Offset 15h defines P which points to the Primary Algorithm Extended Query Address Table.
2. Offset 19h defines A which points to the Alternate Algorithm Extended Query Address Table.
3. SBA is the Start Base Address for each block.
4. In x8 mode, A0 must be set to VIL, otherwise 00h will be output.
Table 25. CFI - Query Address and Data Output
Address
x16
x8(3)
Data
Description
0010h
20h
0011h
22h
0012h
24h
51h
"Q"
51h; "Q"
52h
"R" Query ASCII String 52h; "R"
59h; "Y"
59h
"Y"
0013h
26h
0014h
28h
01h
Primary Vendor:
00h
Command Set and Control Interface ID Code
0015h
2Ah
0016h
2Ch
31h
Primary algorithm extended Query Address Table: P(h)
00h
0017h
2Eh
0018h
30h
00h
Alternate Vendor:
00h
Command Set and Control Interface ID Code
0019h
32h
001Ah(2)
34h
00h
Alternate Algorithm Extended Query address Table
00h
Note: 1. Query Data are always presented on DQ7-DQ0. DQ15-DQ8 are set to '0'.
2. Offset 19h defines A which points to the Alternate Algorithm Extended Query Address Table.
3. In x8 mode, A0 must be set to VIL, otherwise 00h will be output.
35/50