NOTES:
1. All voltages are referenced to ground.
DS2430A
2. VPUP=external pullup voltage.
3. Input load is to ground.
4. An additional reset or communication sequence cannot begin until the reset high time has expired.
5. Read data setup time refers to the time the host must pull the 1-Wire bus low to read a bit. Data is
guaranteed to be valid within 1 µs of this falling edge.
6. VIH is a function of the external pullup resistor and VPUP.
7. Capacitance on the data pin could be 800 pF when power is first applied. If a 5 kΩ resistor is used to
pull up the data line to VPUP, 5 µs after power has been applied the parasite capacitance will not affect
normal communications.
8. tRSTL should be limited to maximum 5 ms. Otherwise the DS2430A may perform a power-on reset.
9. Under certain low voltage conditions VILMAX may have to be reduced to as much as 0.5V to always
guarantee a presence pulse.
10. The Copy Scratchpad takes 10 ms maximum, during which the voltage on the 1-Wire bus must not
fall below 2.8V.
16 of 16