Application examples and ideas
L6562AT
Figure 22. L6562A 80W TM PFC evaluation Figure 23. L6562A 80W TM PFC evaluation
board: compliance to EN61000-3-2
board: compliance to JEIDA-MITI
standard
standard
Measurements @ 230Vac Full load EN61000-3-2 class D limits
1
Measurements @ 100Vac Full load JEIDA-MITI class D limits
1
0.1
0.1
0.01
0.01
0.001
0.001
0.0001
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
Harmonic Order (n)
0.0001
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
Harmonic Order (n)
Vin = 230 Vac - 50 Hz, Pout = 80 W
THD = 10.48%, PF = 0.973
Vin = 100 Vac - 50 Hz, Pout = 80 W
THD = 3.18%, PF = 0.997
Figure 24. L6562A 80W TM PFC evaluation
board: input current waveform
@230 V-50 Hz – 80W load
Figure 25. L6562A 80W TM PFC evaluation
board: input current waveform
@100 V-50 Hz – 80 W load
18/25