DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

L9524C-TR 데이터 시트보기 (PDF) - STMicroelectronics

부품명
상세내역
제조사
L9524C-TR
ST-Microelectronics
STMicroelectronics ST-Microelectronics
L9524C-TR Datasheet PDF : 27 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
Functional description
L9524C
Note:
In order to report the occurrence of any of the above-listed failures to the diesel engine
management system the L9524C provides two protocols: go/no-go protocol for mode 1 and
serial protocol for modes 2 to 6.
The go/no-go protocol is only able to report if any of the above-listed failures occurred. This
is done according to the following table:
Table 7. Go / no-go protocol description
VCI
VDO at “no failure”
VCI off
VCI on
VDOL
VVS
VDO at “any failure”
VVS
VDOL
overcurrent failures are stored until power-down.
The serial protocol is able to report different kinds of failures and to assign them to the
corresponding glow plugs. Therefore, occurring failures are written into an internal 8-bit
failure register:
Table 8. Failure register description
Bit
Meaning of high state
1
Open-load or overcurrent (1) failure at glow plug 1
2
Open-load or overcurrent (1) failure at glow plug 2
3
Open-load or overcurrent (1) failure at glow plug 3
4
Open-load or overcurrent (1) failure at glow plug 4
5
Open-load or overcurrent (1) failure at glow plug 5
6
Open-load or overcurrent (1) failure at glow plug 6
Overcurrent failure at any glow plug (1) or
7
battery voltage (VBAT) is too low (2) (“battery undervoltage”)
One or more of the following failures (“module failure”):
any switch is defect
supply voltage (VVS) is too low (“undervoltage”)
8
supply voltage (VVS) is too high (“overvoltage”)
junction temperature (TJ) is too high
charge pump voltage (VCP) is too low (“charge pump undervoltage”)
battery voltage (VBAT) is too low (2) (“battery under voltage”)
1. overcurrent failures are stored until power-down
2. if battery voltage is too low (“battery under voltage”) bits 7 and 8 are high
Bits 1 to 6 are assigned to the glow plugs. Depending on bit 7 they show open-load (bit 7 is
low) or overcurrent failures (bit 7 is high). Bit 8 shows if there is any of the listed failures
(“module failure”). In case of a battery under voltage failure bits 7 and 8 are high and all
other bits are low as long as there is no overcurrent failure stored.
For transmitting the contents of the failure register the PWM signal applied to the CI pin is
used as clock input: at any falling edge of the CI signal (see section “Control input”) the DO
pin shows the value of the next bit of the bit stream after tDO del.
16/27

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]