Cassette Style
100 Watt AC-DC Converters
S Series PFC
Standards and Approvals
All AC-DC converters correspond to class I equipment.
They are UL recognized according to UL 1950, UL recog-
nized for Canada to CAN/CSA C22.2 No. 950-95 and LGA
approved to IEC/EN 60950 standards.
The units have been evaluated for:
Building in
Basic insulation between input and case, based on 250 V
AC and 400 V DC
Double or reinforced insulation between input and output,
based on 250 V AC and 400 V DC
Basic insulation between output and case based on
200 V AC and DC
Operational insulation between output and output
Connecting the input to a primary or secondary circuit
which is subject to a maximum transient rating of 2500 V
(overvoltage category III based on a 110 V primary cir-
cuit, overvoltage category II based on a 230 V primary
circuit).
The use in a pollution degree 2 environment
The UL 1950 recognition limits the minimum input voltage
to Ui = Ui min + 5 V AC = 90 V AC if the case temperature
exceeds 90°C.
The AC-DC converters are subject to manufacturing sur-
veillance in accordance with the above mentioned UL,
CSA, EN and with ISO 9001 standards.
Isolation
The electric strength test is performed as factory test in ac-
cordance with IEC/EN 60950 and UL 1950 and should not
be repeated in the field. Power-One will not honour any
guarantee claims resulting from electric strength field tests.
Important: Testing by applying AC voltages will result in
high and dangerous leakage currents flowing through
the Y-capacitors (see fig.: Block diagram).
Table 13: Isolation
Characteristic
Input to Input to Output to Output to Unit
case
output
case
output
Electric
strength
test voltage
Required according to
IEC/EN 60950
Actual factory test 1 s
1.5
3.0 1
kVrms
2.1
4.2 1
kV DC
2.8
5.6 1
1.4
0.14
AC test voltage equivalent 2.0
4.0 1
1.0
to actual factory test
0.1
kVrms
Insulation resistance at 500 V DC
>300
>300
>300
>100 2
M
1 In accordance with IEC/EN 60950 only subassemblies are tested in factory with this voltage.
2 Tested at 100 V DC.
For creepage distances and clearances refer to: Technical Information: Safety.
Leakage Currents in AC-DC operation
Leakage currents flow due to internal leakage capacitance
and RFI suppression Y-capacitors. The current values are
proportional to the mains voltage and nearly proportional to
the mains frequency and are specified at an input voltage of
254 V (50 Hz) where phase, neutral and protective earth
are correctly connected as required for class I equipment.
MI
500
1500
10 k220 nF
Under test conditions the leakage current flows through a
measuring instrument (MI) as described in fig.: Measuring
instrument for earth leakage current tests, which takes into
account impedance and sensitivity of a person touching
unearthed accessible parts. The current value is calculated
by dividing the measured voltage by 500 . If inputs of S-
units are connected in parallel, their individual leakage cur-
rents are added.
P
10062
P
Vo+
N
N
Vo
22 nF
V
MI for
earth
leakage
current
Fig. 28
Measuring instrument (MI) for earth leaking current tests
according to IEC/EN 60950.
Fig. 29
Test set-up
Edition 01/01.2001
20/27