MB3886
s OUTPUT STATES DURING PROTECTION CIRCUIT OPERATION
The table below lists the output states with individual protection circuits actuated.
Output terminal
CH1
Protection circuit
OUT1-1
OUT2-1
PSIG1
OUT1-2
Overcurrent
CH1
L
L
L
Active
protection circuit
CH2 Active
Active
H
L
Overvoltage
CH1
L
H
L
Active
protection circuit
CH2 Active
Active
H
L
Short-circuit
CH1
L
L
H
L
protection circuit
CH2
L
L
H
L
CH2
OUT2-2
Active
L
Active
H
L
L
PSIG2
H
L
H
L
H
H
s RESETTING THE LATCH OF EACH PROTECTION CIRCUIT
When each protection circuit (overvoltage, overcurrent, or short-circuit protection circuit) detects an abnormal
state or event, it sets the latch to fix the output at the “L” level. The PSIG1 terminal (pin 1) or PSIG2 terminal
(pin 30) is fixed at the “L” level when the overvoltage or overcurrent protection circuit detects an overvoltage or
overcurrent.
When a protection circuit operates, the latch can be released by reentering the power supply or setting the CTL1
terminal (pin 2) or CTL2 terminal (pin 29) to the “L” level.
The overvoltage and overcurrent protection circuits work for each channel separately. Use the CTL1 and CTL2
terminals to unlatch CH1 and CH2, respectively.
The short-circuit protection circuit fixes the outputs of both channels upon detection of a short circuit even on
either. Set both of the CTL1 and CTL2 terminals to the “L” level to unlatch the two channels.
Operation circuit
CTL1
Unlatching Conditions
CTL2
Overcurrent protection
circuit
Overvoltage protection
circuit
OPEN
L
OPEN
L
OPEN
Short-circuit protection
circuit
L
OPEN
L
: Unlatched, × : Not unlatched
OPEN
OPEN
L
L
OPEN
OPEN
L
L
Channels unlatched
CH1