512Mb: x16, x32 Mobile LPDDR SDRAM
Electrical Specifications – AC Operating Conditions
Table 12: Electrical Characteristics and Recommended AC Operating Conditions (Continued)
Notes 1–9 apply to all the parameters in this table; VDD/VDDQ = 1.70–1.95V
-5
-54
-6
Parameter
Symbol Min Max Min Max Min Max
PRECHARGE command
period
tRP
15
–
16.2
–
18
–
DQS read preamble CL = 3 tRPRE
0.9
1.1
0.9
1.1
0.9
1.1
CL = 2 tRPRE
0.5
1.1
0.5
1.1
0.5
1.1
DQS read postamble
tRPST
0.4
0.6
0.4
0.6
0.4
0.6
Active bank a to active
bank b command
tRRD
10
–
10.8
–
12
–
Read of SRR to next valid
command
tSRC CL + 1 – CL + 1 – CL + 1 –
SRR to read
tSRR
2
–
2
–
2
–
Internal temperature sen-
tTQ
2
–
2
–
2
–
sor valid temperature out-
put enable
DQS write preamble
tWPRE 0.25
–
0.25
–
0.25
–
DQS write preamble setup tWPRES
0
–
0
–
0
–
time
DQS write postamble
tWPST
0.4
0.6
0.4
0.6
0.4
0.6
Write recovery time
tWR
15
–
15
–
15
–
Internal WRITE-to-READ
tWTR
2
–
2
–
1
–
command delay
Exit power-down mode to
tXP
2
–
2
–
1
–
first valid command
Exit self refresh to first
valid command
tXSR
112.5
–
112.5
–
112.5
–
-75
Min Max
22.5
–
0.9 1.1
0.5 1.1
0.4 0.6
15
–
CL + 1 –
2
–
2
–
0.25
–
0
–
0.4 0.6
15
–
1
–
1
–
112.5 –
Unit Notes
ns
tCK
tCK
tCK
ns
tCK
tCK
ms
tCK
ns 25, 26
tCK
27
ns
28
tCK
tCK
ns
29
Notes:
1. All voltages referenced to VSS.
2. All parameters assume proper device initialization.
3. Tests for AC timing and electrical AC and DC characteristics may be conducted at nomi-
nal supply voltage levels, but the related specifications and device operation are guar-
anteed for the full voltage ranges specified.
4. The circuit shown below represents the timing reference load used in defining the rele-
vant timing parameters of the device. It is not intended to be either a precise represen-
tation of the typical system environment or a depiction of the actual load presented by
a production tester. System designers will use IBIS or other simulation tools to correlate
the timing reference load to system environment. Specifications are correlated to pro-
duction test conditions (generally a coaxial transmission line terminated at the tester
electronics). For the half-strength driver with a nominal 10pF load, parameters tAC and
tQH are expected to be in the same range. However, these parameters are not subject to
production test but are estimated by design/characterization. Use of IBIS or other simu-
PDF: 09005aef83dd2b3e
t67m_512mb_mobile_lpddr.pdf - Rev. H 06/13 EN
28
Micron Technology, Inc. reserves the right to change products or specifications without notice.