Philips Semiconductors
P89LPC9102/9103/9107
8-bit microcontrollers with two-clock accelerated 80C51 core
Table 6: P89LPC9107 pin description …continued
Symbol
Pin
Type Description
P1.0 to P1.2,
P1.5
I/O
Port 1: Port 1 is an I/O port with a user-configurable output type. During reset Port 1
latches are configured in the input-only mode with the internal pull-up disabled. The
operation of the configurable Port 1 pins as inputs and outputs depends upon the port
configuration selected. Each of the configurable port pins are programmed
independently. Refer to Section 8.12.1 “Port configurations” and Table 12 “Static
characteristics” for details. P1.5 is input-only.
All pins have Schmitt triggered inputs.
Port 1 also provides various special functions as described below:
P1.0/TXD
6
I/O
P1.0 — Port 1 bit 0.
O
TXD — Serial port transmitter data.
P1.1/RXD
9
I/O
P1.1 — Port 1 bit 1.
I
RXD — Serial port receiver data.
P1.2/T0
7
I/O
P1.2 — Port 1 bit 2.
I/O
T0 — Timer/counter 0 external count input or overflow/PWM output.
P1.5/RST
3
I
P1.5 — Port 1 bit 5 (input-only).
I
RST — External Reset input during Power-on or if selected via UCFG1. When
functioning as a reset input a LOW on this pin resets the microcontroller, causing I/O
ports and peripherals to take on their default states, and the processor begins
execution at address 0. When using an oscillator frequency above 12 MHz, the
reset input function of P1.5 must be enabled. An external circuit is required to
hold the device in reset at power-up until VDD has reached its specified level.
When system power is removed VDD will fall below the minimum specified
operating voltage. When using an oscillator frequency above 12 MHz, in some
applications, an external brownout detect circuit may be required to hold the
device in reset when VDD falls below the minimum specified operating voltage.
VSS
4
I
Ground: 0 V reference.
VDD
10
I
Power supply: This is the power supply voltage for normal operation as well as Idle
mode and Power-down mode.