10. Reliability Test
No
Test Item
Test Condition
Remark
1 High Temperature Storage Test Ta = +60C, 240 hrs
2 Low Temperature Storage Test Ta = -20C, 240 hrs
3 Low Temperature Operation Test Ta = 0C, 240 hrs
High Temperature & High Humidity Ta = +50C, 80%RH, 240 hrs
4
Operation Test
(No Condensation)
Thermal Cycling Test
5
(non-operating)
Vibration Test
6
(non-operating)
0CÅÆ+25CÅÆ+60C, 50 Cycles
1Hr 0.5Hr 1Hr
Frequency:10 ~ 57 HZ , Amplitude:0.15 mm
58~500Hz, 1G
Sweep time: 11 min
Test Period: 3 hrs (1 hr for each direction of X,
Shock Test
7
(non-operating)
Y, Z)
80G, 6ms, X,Y, Z
1 times for each direction
Ta: ambient temperature
[Judgement Criteria]
Under the display quality test conditions with normal operation state , there should be no
change which may affect practical display function.
T-51410D104-FW-P-AD
OPTREX CORPORATION
Page-17/18