S6B0716
33COM/100SEG DRIVER & CONTROLLER FOR STN LCD
Column Address Circuit
Column Address circuit has a 8-bit preset counter that provides Column Address to the Display Data RAM as shown
in figure 8. When set Column Address MSB / LSB instruction is issued, 8-bit [Y7:Y0] is updated. And, since this
address is increased by 1 each a read or write data instruction, microprocessor can access the display data
continuously. However, the counter is not increased and locked if a non-existing address above 84H. It is unlocked
if a Column Address is set again by set Column Address MSB / LSB instruction. And the Column Address counter is
independent of page address register.
ADC Select instruction makes it possible to invert the relationship between the column address and the segment
outputs. It is necessary to rewrite the display data on built-in RAM after issuing ADC Select instruction. Refer to the
following figure 7.
SEG output
-
Column address [Y7:Y0]
Display data
LCD panel display
( ADC = 0 )
00H~
0FH
×
Not
outputted
SEG
0
10H
1
SEG
1
01H
0
SEG
2
02H
0
... ...
... ...
... ...
SEG
97
71H
0
SEG
98
72H
1
SEG
99
73H
1
-
74H~
83H
0
Not
outputted
LCD panel display
( ADC = 1 )
Not
outputted
... ...
Figure 7. The Relationship between the Column Address and the Segment Outputs
Not
outputted
Segment Control Circuit
This circuit controls the display data by the display ON / OFF, reverse display ON / OFF and entire display ON / OFF
instructions without changing the data in the display data RAM.