MITSUBISHI< LINEAR IC >
M52749FP
BUS CONTROLLED 3CH VIDEO PRE-AMP FOR CRT DISPLAY MONITOR
Note13) Measure the amplitude output at OUT(33,38,41). The measured value is called VOUT(33,38,41).
Sub contrast conrol characteristics VSC1 is calculated by the equation below:
VOUT
VSC1=20 LOG
(dB)
0.7
Note14) Relative characteristics VSC1 is calculated by the equation below:
VSC1=VOUT(33)/VOUT(38) , VOUT(38)/VOUT(41) , VOUT(41)/VOUT(33)
Note15) Measuring condition and procedure are the same as described in Note13.
Note16) Measuring condition and procedure are the same as described in Note14.
Note17) Measure the amplitude output at OUT(33,38,41). The measured value is called VOUT(33,38,41).
Note18) Measuring condition and procedure are the same as described in Note14.
Note19) Measure the amplitude output at OUT(33,38,41). The measured value is called VMSC.
Note20) Relative characteristics VMSC is calculated by the equation below:
VMSC=VOUT(33)/VOUT(38) , VOUT(38)/VOUT(41) , VOUT(41)/VOUT(33)
Note21) Measure the amplitude output at OUT(33,38,41). The measured value is called VOUT(33,38,41),
and is treated as ABL1.
Note22) Relative characteristics ABL1 is calculated by the equation below:
ABL1=VOUT(33)/VOUT(38) , VOUT(38)/VOUT(41) , VOUT(41)/VOUT(33)
Note23) Measuring condition and procedure are the same as described in Note21.
Note24) Measuring condition and procedure are the same as described in Note22.
Note25) Measure the DC voltage at OUT(33,38,41) with a voltmeter. The measured value is called
VOUT(33,38,41), and is treated as VB1.
Note26) Relative characteristics VB1 is calculated by the difference in the output between the channels.
VB1=VOUT(33)Å|VOUT(38) , VOUT(38)Å|VOUT(41) , VOUT(41)Å|VOUT(33)
Note27) Measuring condition and procedure are the same as described in Note25.
Note28) Measuring condition and procedure are the same as described in Note26.
Note29) Measuring condition and procedure are the same as described in Note25.