TS4962
Absolute maximum ratings and operating conditions
Table 3. Operating conditions
Symbol
Parameter
Value
Unit
VCC
Supply voltage(1)
2.4 to 5.5
V
VIC
Common mode input voltage range(2)
0.5 to VCC-0.8
V
VSTBY
Standby voltage input: (3)
Device ON
Device OFF
1.4 ≤VSTBY ≤ VCC
V
GND ≤ VSTBY ≤ 0.4 (4)
RL
Load resistor
≥4
Ω
Thermal resistance junction to ambient
Rthja
DFN8 package(5)
50
°C/W
≤ ≤ 1. For VCC between 2.4V and 2.5V, the operating temperature range is reduced to 0°C Tamb 70°C.
2. For VCC between 2.4V and 2.5V, the common mode input range must be set at VCC/2.
3. Without any signal on VSTBY, the device will be in standby.
4. Minimum current consumption is obtained when VSTBY = GND.
5. When mounted on a 4-layer PCB.
7/46