W83L785R/W83L785G
6.5.3.2. Interrupt Mode:
At this mode, temperature exceeding TO causes the OVT# output activated indefinitely until reset by
reading interrupt status register. Temperature exceeding TO, then OVT# asserted, and then
temperature going below THYST will also cause the OVT# activated indefinitely until reset by reading
temperature sensor1 or sensor2 registers. Once the OVT# is activated by exceeding TO, then reset, if
the temperature remains above THYST, the OVT# will not be activated again. (Figure 5)
To
THYST
(Comparator Mode; default)
(Interrupt Mode)
OVT#
OVT#
*
*
*
*
*Interrupt Reset when Interrupt Status Register is read
Figure 5
6.5.4 Temperature Fault (Temp_fault #)
W83L785R/G provides a good protection for temperature. Setting pin11 (TEMP_FAULT#) to monitor
temperature and enable TEMP_FAULT# function. When VTIN1 (Pin19) or VTIN (Pin18) temperature
exceeds Temperature fault limit in CR53,or R54 pin11 TEMP_FAULT# will be asserted. (Figure 6)
TEMP_FAULT limit
TEMP_FAULT#
Figure 6. TEMP_FAULT