Table 1. Absolute Maximum Ratings [1]
Parameter
RF Input Power
DC Supply Voltage
Reference Voltage
Control Voltage
Storage Temperature
Symbol
Min
Pin
–
Vcc
0
Vref
0
Vcont
0
Tstg
-55
Nominal
Max
Unit
–
10.0
dBm
3.4
5.0
V
2.85
3.3
V
2.85
3.3
V
–
+125
°C
Table 2. Recommended Operating Condition
Parameter
DC Supply Voltage
DC Reference Voltage
Mode Control Voltage
– High Power Mode
– Low Power Mode
Operating Frequency
Ambient Temperature
Symbol
Min
Nominal
Max
Unit
Vcc
3.2
3.4
4.2
V
Vref
2.75
2.85
2.95
V
Vcont
0
0
0.5
V
Vcont
2.0
2.85
3.0
V
Fo
824
849
MHz
Ta
-30
25
85
°C
Table 3. Power Range Truth Table
Power Mode
Symbol
Vref
Vcont [2]
Range
High Power Mode
PR2
2.85
Low
~ 28dBm
Low Power Mode
PR1
2.85
High
~ 16dBm
Shut Down Mode
–
0
–
–
Notes:
1. No damage assuming only one parameter is set at limit at a time with all other parameters set at or below nominal value.
2. High (2.0–3.0V), Low (0.0V–0.5V).
2