(3). If both (1) and (2) are not true and KEEP_STOP (see INDEX 60h) is set to 0:
(a). When PWMOUT duty-cycle decrease to STOP_DUTY(≠ 00h), obviously the duty-cycle will
decrease to 00h next, F71805 will keep duty-cycle at 00h 3 seconds1. After that, F71805
starts to compare current fan count and expected count in order to increase or decrease its
duty-cycle. This ensures that if there is any glitch during the 3 seconds1 period, F71805 will
ignore it.
(b). When PWMOUT duty-cycle increase from 00h to START_DUTY(≠ 00h), F71805 also will
keep duty-cycle at START_DUTY 3 seconds1. After that, F71805 starts to compare current
fan count and expected count in order to increase or decrease its duty-cycle. This ensures
that if there is any glitch during the 3 seconds1 period, F71805 will ignore it.
Note 1: The period of HOLD_DUTY_TIME can be programmed at INDEX 67h of FAN1.
START
STOP
START
STOP
6.2.6 FAN_FAULT#
Fan_Fault will be asserted ( PME# Pin 81) when the fan speed doesn’t meet the expected fan speed
within a programmable period (default is 3 seconds) or when PWMOUT duty-cycle is 100%.
17