MAX8952
2.5A Step-Down Regulator
with Remote Sense in 2mm x 2mm WLP
ELECTRICAL CHARACTERISTICS (continued)
(VIN1 = VIN2 = 3.6V, VAGND = VPGND = 0V, VDD = 1.8V, TA = -40°C to +85°C, unless otherwise noted. Typical values are at TA =
+25°C.) (Note 2)
PARAMETER
Minimum Duty Cycle
Maximum Duty Cycle
Minimum On- and Off-Time
OUT Discharge Resistance
SNS+, SNS- Input Impedance
Time Delay from PWM
to Power-Save Mode
Time Delay from Power-Save
Mode to PWM
CONDITIONS
Forced-PWM mode (FPWM_EN = 1),
minimum duty cycle = 0%
During shutdown or UVLO, from SNS+ to PGND
VOUT = 0.77V (OUT_MODEx [5:0] = 0b000000)
Time required for error amplifier to stabilize before
switching mode
Time required for error amplifier to stabilize before
switching mode
MIN TYP MAX UNITS
16
%
60
%
30
40
50
ns
650
Ω
400
600
850
kΩ
70
µs
140
µs
SYNCHRONIZATION (SYNC)
SYNC[1:0] = 00
18.9 26.0 38.0
SYNC Capture Range
SYNC[1:0] = 1X
14.2 19.2 28.5 MHz
SYNC[1:0] = 01
9.5
13.0 19.0
SYNC Pulse Width
13
ns
PROTECTION CIRCUITS
Thermal-Shutdown Hysteresis
20
°C
Thermal Shutdown
+160
°C
Note 2: All devices are 100% production tested at TA = +25°C. Limits over the operating temperature range are guaranteed by
design.
Maxim Integrated
5