Si3050 + Si3011/18/19
tr
tf
PCLK
FSYNC
DRX
th1
tfp
tsu2
tsu2
th2
td1
td2
td3
DTX
Figure 6. GCI Highway Interface Timing Diagram (2x PCLK Mode)
Table 10. Digital FIR Filter Characteristics—Transmit and Receive
(VD = 3.0 to 3.6 V, Sample Rate = 8 kHz, TA = 0 to 70 °C)
Parameter
Symbol
Min
Typ
Passband (0.1 dB)
Passband (3 dB)
Passband Ripple Peak-to-Peak
F(0.1 dB)
0
—
F(3 dB)
0
—
–0.1
—
Stopband
—
4.4
Stopband Attenuation
–74
—
Group Delay
tgd
—
12/Fs
Note: Typical FIR filter characteristics for Fs = 8000 Hz are shown in Figures 7, 8, 9, and 10.
Max
3.3
3.6
0.1
—
—
—
Unit
kHz
kHz
dB
kHz
dB
s
Table 11. Digital IIR Filter Characteristics—Transmit and Receive
(VD = 3.0 to 3.6 V, Sample Rate = 8 kHz, TA = 0 to 70 °C)
Parameter
Symbol
Min
Typ
Max
Unit
Passband (3 dB)
Passband Ripple Peak-to-Peak
F(3 dB)
0
—
–0.2
—
3.6
kHz
0.2
dB
Stopband
—
4.4
—
kHz
Stopband Attenuation
–40
—
—
dB
Group Delay
tgd
—
1.6/Fs
—
s
Note: Typical IIR filter characteristics for Fs = 8000 Hz are shown in Figures 11, 12, 13, and 14. Figures 15 and 16 show
group delay versus input frequency.
14