Delete Associated Module - Command Code = 3B
This command removes the association between the current module and
another module.
Delete Associated Module Command and Response
Command
Start Command Param 1 Param 2 Param 3 Param 4
End
3C
3B
SrcAdr3 SrcAdr2 SrcAdr1 SrcAdr0
3E
Response
Start Response Param 1
End
3C
3B
Status
3E
Figure 49: Delete Associated Module Command and Response
Associated modules can only be removed one by one using this command.
Once a module is deleted, the AP cannot communicate with the ED until
a new link is established and the modules become associated again.
This requires a power cycle or a reset on the ED. The parameters of this
command contain the address of the module to be deleted, where SrcAdr3
is the MSB and SrcAdr0 is the LSB.
The response parameter indicates if the command was successful (00) or if
there was an error (01).
Reset Module - Command Code = 3C
This command initiates a full module reset.
Reset Module Command and Response
Command
Start Command End
3C
3C
3E
Response
Start Response Param 1
End
3C
3C
Status
3E
Figure 50: Reset Module Command and Response
This serial command is the equivalent of pulling the RESET line low.