DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

DBQ0135V2 데이터 시트보기 (PDF) - Unspecified

부품명
상세내역
제조사
DBQ0135V2 Datasheet PDF : 32 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
DBQ/DVQ Series
420W Digital Fully Regulated Intermediate
DC-DC Bus Converter
DBQ0135V2 FUNCTIONAL SPECIFICATIONS (CONT.)
PMBus
Conditions
Minimum Typical/Nominal Maximum
Units
PMBus GENERAL
PMBus REV. 1.2. SMBALERT# is supported. PEC is supported. Linear data format used.
Bus speed
400
kHz
Logic high input
2
3.3
Vdc
Logic low input
0
0.8
Vdc
Logic high output
2.4
3.6
Vdc
Logic low output
-0.1
0.4
Vdc
PMBus ADDRESSING
If the calculated PMBus address is 0d, 11d or 12d, SA0 or SA1 lefts open, default PMBus address 119d is assigned instead. PMBus address = 8x(SA0 value) + (SA1 value). SA0,
SA1 value VS resistor connected to GND.
0
10
1
22
2
33
3
47
4
68
5
100
6
150
7
220
PMBus MONITORING ACCURACY
VIN_READ
-2.5
2.5
%
VOUT_READ
-1
1
%
IOUT_READ
-1
1
A
TEMP_READ
-5
5
°C
DIGITAL INTERFACE SPECIFICATIONS (PMBUS MONITORING & FUNCTIONAL DESCRIPTION)
Fault Protection Specifications
Output Voltage, Over Voltage protection, OVP
Factory default
14.4
V
VOUT_OV_FAULT_LIMIT, Configurable via PMBus
>VOUT_OV_WARM_LIMIT
8.1
15.6
V
Restart delay (default, Configurable via PMBus)
500
mS
VIN_OV_FAULT_LIMIT (Configurable via
PMBus)
>VIN_OV_WARM_LIMIT
34
110
V
Restart delay (default, Configurable via PMBus)
200
mS
Input Voltage, Input Under Voltage Protec-
tion, UVLO
Factory default
32
V
Setpoint accuracy
-2
2
%
VIN_UV_FAULT_LIMIT (Configurable via
PMBus)
<VIN_UV_WARM_LIMIT <VIN_OV_FAULT_LIMIT
32
75
V
Restart delay (default, Configurable via PMBus)
200
mS
Over Current Protection, OCP
Setpoint accuracy (Io)
-3
3
%
(factory default)
42
A
IOUT_OC_FAULT_LIMIT (Configurable via
PMBus)
>IOUT_OC_WARN_LIMT
0
50
A
Restart delay (default, Configurable via PMBus)
500
mS
Over Temperature Protection, OTP
OT_FAULT_LIMIT (factory default)
120
°C
OT_FAULT_LIMIT (Configurable via PMBus)
>OT_WARM_LIMIT
0
30
150
°C
OTP accuracy (factory default)
5
5
°C
Restart delay (default, Configurable via PMBus)
500
mS
www.murata-ps.com/support
MDC_DBQ Series.B02Δ Page 14 of 31