DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

AS3932 데이터 시트보기 (PDF) - austriamicrosystems AG

부품명
상세내역
제조사
AS3932
AMSCO
austriamicrosystems AG AMSCO
AS3932 Datasheet PDF : 33 Pages
First Prev 21 22 23 24 25 26 27 28 29 30 Next Last
AS3932
Data Sheet - Detailed Description
If the preamble is detected correctly the correlator keeps searching for a data pattern. The duration of the preamble plus the pattern should not
be longer than 40 bits (see bit rate definition in Table 18). The data pattern can be defined by the user and consists of two bytes which are stored
in the registers R5<7:0> and R6<7:0>. The two bytes define the pattern consisting of 16 half bit periods. This means the pattern and the bit
period can be selected by the user. The only limitation is that the pattern (in combination with preamble) must obey Manchester coding and
timing. It must be noted that according to Manchester coding a down-to-up bit transition represents a symbol "0", while a transition up-to-down
represents a symbol "1". If the default code is used (96 [hex]) the binary code is (10 01 01 10 01 10 10 01). MSB has to be transmitted first.
The user can also select (R1<2>) if single or double data pattern is used for wake-up. In case double pattern detection is set, the same pattern
has to be repeated 2 times.
Additionally it is possible to set the number of allowed missing zero bits (not symbols) in the received bitstream (R2<6:5>), as shown in the Table
19.
Table 19. Allowed Pattern Detection Errors
R2<6>
R2<5>
Maximum allowed error in the pattern detection
0
0
No error allowed
0
1
1 missed zero
1
0
2 missed zeros
1
1
3 missed zeros
If the pattern is matched the wake-up interrupt is displayed on the WAKE output. In case the Manchester decoder is enabled (R1<3>) the data
coming out from the DAT pin are decoded and the clock is recovered on the pin DAT_CL.
The data coming out from the DAT pin are stable (and therefore can be acquired) on the rising edge of the CL_DAT clock, as shown in Figure 17.
Figure 17. Synchronization of Data with Recovered Manchester Clock
C L_ DA T
D AT
If the pattern detection fails the internal wake-up (on all active channels) is terminated with no signal sent to MCU and the false wakeup register
will be incremented (R13<7:0>).
8.7 Wakeup Protocol - Carrier Frequency 125 kHz
The wake-up state is terminated with the direct command ‘clear_wake’ Table 12. This command terminates the MCU activity. The termination
can also be automatic in case there is no response from MCU. The time out for automatic termination is set in a register R7<7:5>, as shown in
the Table 20.
Table 20. Timeout Setup
R7<7>
R7<6>
R7<5>
Time out
0
0
0
0 sec
0
0
1
50 msec
0
1
0
100 msec
0
1
1
150 msec
1
0
0
200 msec
1
0
1
250 msec
www.austriamicrosystems.com/AS3932
Revision 1.2
22 - 33

Share Link: 