DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

HI-3583PCIF-10_06 데이터 시트보기 (PDF) - Holt Integrated Circuits

부품명
상세내역
제조사
HI-3583PCIF-10_06
HOLTIC
Holt Integrated Circuits HOLTIC
HI-3583PCIF-10_06 Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
HI-3582, HI-3583
FUNCTIONAL DESCRIPTION (cont.)
ARINC 429 DATA FORMAT
Control register bit CR15 is used to control how individual bits in the
received or transmitted ARINC word are mapped to the HI-3582/
HI-3583 data bus during data read or write operations. The
following table describes this mapping:
BYTE 1
DATA BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD
BUS 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
ARINC 13 12 11 10 9 31 30 32 1 2 3 4 5 6 7 8
BIT
CR15=0
ARINC 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
BIT
CR15=1
BYTE 2
DATA BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD
BUS 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
ARINC
BIT
CR15=0
29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14
ARINC
BIT
CR15=1
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
THE RECEIVERS
ARINC BUS INTERFACE
Figure 1 shows the input circuit for each receiver. The ARINC 429
specification requires the following detection levels:
STATE
ONE
NULL
ZERO
DIFFERENTIAL VOLTAGE
+6.5 Volts to +13 Volts
+2.5 Volts to -2.5 Volts
-6.5 Volts to -13 Volts
RIN1A
OR
RIN2A
RIN1B
OR
RIN2B
vDD
GND
vDD
DIFFERENTIAL
AMPLIFIERS
COMPARATORS
ONES
NULL
ZEROES
GND
FIGURE 1. ARINC RECEIVER INPUT
The HI-3582/HI-3583 guarantee recognition of these levels with a
common mode Voltage with respect to GND less than ±4V for the
worst case condition (3.0V supply and 13V signal level).
The tolerances in the design guarantee detection of the above
levels, so the actual acceptance ranges are slightly larger. If the
ARINC signal is out of the actual acceptance ranges, including the
nulls, the chip rejects the data.
RECEIVER LOGIC OPERATION
Figure 2 shows a block diagram of the logic section of each receiver.
BIT TIMING
The ARINC 429 specification contains the following timing specifi-
cation for the received data:
BIT RATE
PULSE RISE TIME
PULSE FALL TIME
PULSE WIDTH
HIGH SPEED LOW SPEED
100K BPS ± 1% 12K -14.5K BPS
1.5 ± 0.5 µsec 10 ± 5 µsec
1.5 ± 0.5 µsec 10 ± 5 µsec
5 µsec ± 5% 34.5 to 41.7 µsec
The HI-3582/HI-3583 accept signals that meet these specifica-
tions and rejects signals outside the tolerances. The way the logic
operation achieves this is described below:
1. Key to the performance of the timing checking logic is an
accurate 1MHz clock source. Less than 0.1% error is recom-
mended.
2. The sampling shift registers are 10 bits long and must
show three consecutive Ones, Zeros or Nulls to be consid-
ered valid data. Additionally, for data bits, the One or Zero in
the upper bits of the sampling shift registers must be followed
by a Null in the lower bits within the data bit time. For a Null in
the word gap, three consecutive Nulls must be found in both
the upper and lower bits of the sampling shift register. In this
manner the minimum pulse width is guaranteed.
3. Each data bit must follow its predecessor by not less than
8 samples and no more than 12 samples. In this manner the
bit rate is checked. With exactly 1MHz input clock frequency,
the acceptable data bit rates are as follows:
DATA BIT RATE MIN
DATA BIT RATE MAX
HIGH SPEED LOW SPEED
83K BPS
125K BPS
10.4K BPS
15.6K BPS
4. The Word Gap timer samples the Null shift register every
10 input clocks (80 for low speed) after the last data bit of a
valid reception. If the Null is present, the Word Gap counter
is incremented. A count of 3 will enable the next reception.
HOLT INTEGRATED CIRCUITS
4

Share Link: 