GaAs Components
Permissible Total Power Dissipation
in DC Operation
1600
mW
Ptot DC
EHT08747
CGY 196
1200
1000
800
600
400
200
0
0
50
100 ˚C 150
TS
b) Pulsed Operation
For the calculation of the permissible pulse load Ptot-max the following formula is
applicable:
Ptot-max = Ptot-DC × Pulse factor = Ptot-DC × (Ptot-max/Ptot-DC)
Use the values for Ptot-DC as derived from the above diagram and for the pulse
factor = Ptot-max/Ptot-DC from the following diagram to get a specific value.
Data Sheet
4