TYPICAL PERFORMANCE CURVES (TA = 25 °C)
NORMALIZED TURN-ON TIME vs.
AMBIENT TEMPERATURE
3.0
Normalized to 1.0
at TA = 25°C,
2.5
IF = 10 mA,
VL = 5V,
RL = 500 Ω
2.0
1.5
1.0
0.5
0.0
-25
0
25
50
75
100
Ambient Temperature, TA (°C)
PS7142-2A, PS7142L-2A
NORMALIZED TURN-OFF TIME vs.
AMBIENT TEMPERATURE
3.0
Normalized to 1.0
at TA = 25°C,
2.5
IF = 10 mA,
VL = 5V,
RL = 500 Ω
2.0
1.5
1.0
0.5
0.0
-25
0
25
50
75
100
Ambient Temperature, TA (°C)