NTD20N06
ELECTRICAL CHARACTERISTICS (TJ = 25°C unless otherwise noted)
Characteristic
OFF CHARACTERISTICS
Drain−to−Source Breakdown Voltage (Note 3)
(VGS = 0 Vdc, ID = 250 mAdc)
Temperature Coefficient (Positive)
Zero Gate Voltage Drain Current
(VDS = 60 Vdc, VGS = 0 Vdc)
(VDS = 60 Vdc, VGS = 0 Vdc, TJ = 150°C)
Gate−Body Leakage Current (VGS = ± 20 Vdc, VDS = 0 Vdc)
ON CHARACTERISTICS (Note 3)
Gate Threshold Voltage (Note 3)
(VDS = VGS, ID = 250 mAdc)
Threshold Temperature Coefficient (Negative)
Static Drain−to−Source On−Resistance (Note 3)
(VGS = 10 Vdc, ID = 10 Adc)
Static Drain−to−Source On−Voltage (Note 3)
(VGS = 10 Vdc, ID = 20 Adc)
(VGS = 10 Vdc, ID = 10 Adc, TJ = 150°C)
Forward Transconductance (Note 3) (VDS = 7.0 Vdc, ID = 6.0 Adc)
DYNAMIC CHARACTERISTICS
Input Capacitance
Output Capacitance
Transfer Capacitance
(VDS = 25 Vdc, VGS = 0 Vdc,
f = 1.0 MHz)
SWITCHING CHARACTERISTICS (Note 4)
Turn−On Delay Time
Rise Time
Turn−Off Delay Time
Fall Time
Gate Charge
(VDD = 30 Vdc, ID = 20 Adc,
VGS = 10 Vdc,
RG = 9.1 W) (Note 3)
(VDS = 48 Vdc, ID = 20 Adc,
VGS = 10 Vdc) (Note 3)
SOURCE−DRAIN DIODE CHARACTERISTICS
Forward On−Voltage
(IS = 20 Adc, VGS = 0 Vdc) (Note 3)
(IS = 20 Adc, VGS = 0 Vdc, TJ = 150°C)
Reverse Recovery Time
(IS = 20 Adc, VGS = 0 Vdc,
dIS/dt = 100 A/ms) (Note 3)
Reverse Recovery Stored Charge
3. Pulse Test: Pulse Width ≤ 300 ms, Duty Cycle ≤ 2%.
4. Switching characteristics are independent of operating junction temperatures.
Symbol
V(BR)DSS
IDSS
IGSS
VGS(th)
RDS(on)
VDS(on)
gFS
Ciss
Coss
Crss
td(on)
tr
td(off)
tf
QT
Q1
Q2
VSD
trr
ta
tb
QRR
Min
Typ
Max
Unit
Vdc
60
71.7
−
−
79.4
−
mV/°C
mAdc
−
−
1.0
−
−
10
−
−
±100
nAdc
Vdc
2.0
2.91
4.0
−
6.9
−
mV/°C
mW
−
37.5
46
Vdc
−
0.78 1.10
−
1.57
−
−
13.2
−
mhos
−
725 1015
pF
−
213
300
−
58
120
−
9.5
20
ns
−
60.5
120
−
27.1
60
−
37.1
80
−
21.2
30
nC
−
5.6
−
−
7.3
−
−
1.0
1.2
Vdc
−
0.87
−
−
42.9
−
ns
−
33
−
−
9.9
−
−
0.084
−
mC
ORDERING INFORMATION
Device
Package
Shipping†
NTD20N06
NTD20N06G
DPAK
DPAK
(Pb−Free)
75 Units/Rail
75 Units/Rail
NTD20N06−1
NTD20N06−1G
DPAK−3
DPAK
(Pb−Free)
75 Units/Rail
75 Units/Rail
NTD20N06T4
DPAK
2500 Tape & Reel
NTD20N06T4G
DPAK
(Pb−Free)
2500 Tape & Reel
†For information on tape and reel specifications, including part orientation and tape sizes, please refer to our Tape and Reel Packaging
Specifications Brochure, BRD8011/D.
http://onsemi.com
2