2-channel analog multiplexer/demultiplexer
8 Limiting values
Table 5. Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V).
Symbol
Parameter
Conditions
Min
Max Unit
VCC
VI
IIK
ISK
VSW
ISW
ICC
IGND
Tstg
Ptot
supply voltage
input voltage
input clamping current
switch clamping current
switch voltage
switch current
supply current
ground current
storage temperature
total power dissipation
VI < -0.5 V or VI > VCC + 0.5 V
VI < -0.5 V or VI > VCC + 0.5 V
enable and disable mode
VSW > -0.5 V or VSW < VCC + 0.5 V
Tamb = -40 °C to +125 °C
-0.5
[1] -0.5
-50
-
[2] -0.5
-
-
-100
-65
[3]
-
+6.5 V
+6.5 V
-
mA
±50
mA
VCC + 0.5 V
±50
mA
100
mA
-
mA
+150 °C
250
mW
[1] The minimum input voltage rating may be exceeded if the input current rating is observed.
[2] The minimum and maximum switch voltage ratings may be exceeded if the switch clamping current rating is observed.
[3] For TSSOP8 packages: above 55 °C the value of Ptot derates linearly with 2.5 mW/K.
For VSSOP8 packages: above 110 °C the value of Ptot derates linearly with 8.0 mW/K.
For XSON8 and XQFN8 packages: above 118 °C the value of Ptot derates linearly with 7.8 mW/K.
9 Recommended operating conditions
Table 6. Operating conditions
Symbol Parameter
VCC
supply voltage
VI
input voltage
VSW
switch voltage
Tamb
ambient temperature
Δt/ΔV
input transition rise and fall rate
Conditions
enable and disable mode
VCC = 1.65 V to 2.7 V
VCC = 2.7 V to 5.5 V
Min
1.65
0
[1]
0
-40
[2]
-
[2]
-
Max
5.5
5.5
VCC
+125
20
10
Unit
V
V
V
°C
ns/V
ns/V
[1] To avoid sinking GND current from terminal Z when switch current flows in terminal Yn, the voltage drop across the bidirectional switch must not exceed
0.4 V. If the switch current flows into terminal Z, no GND current will flow from terminal Yn. In this case, there is no limit for the voltage drop across the
switch.
[2] Applies to control signal levels.
74LVC1G53
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 11 — 16 January 2018
© Nexperia B.V. 2018. All rights reserved.