Nexperia
Symbol Parameter
Conditions
IBHLO
IBHHO
bus hold LOW
overdrive
current
bus hold HIGH
overdrive
current
VCC = 1.95 V
VCC = 2.7 V
VCC = 3.6 V
VCC = 1.95 V
VCC = 2.7 V
VCC = 3.6 V
74LVC16244A-Q100;
74LVCH16244A-Q100
16-bit buffer/line driver; 5 V input/output tolerant; 3-state
-40 °C to +85 °C
-40 °C to +125 °C Unit
Min Typ [1] Max Min Max
[3] [5] 200
-
-
200
- μA
300
-
-
300
- μA
500
-
-
500
- μA
[3] [5] -200
-
-
-200
- μA
-300
-
-
-300
- μA
-500
-
-
-500
- μA
[1] All typical values are measured at VCC = 3.3 V and Tamb = 25 °C.
[2] The bus hold circuit is switched off when VI > VCC allowing 5.5 V on the input terminal.
[3] Valid for data inputs only. Control inputs do not have a bus hold circuit.
[4] The specified sustaining current at the data input holds the input below the specified VI level.
[5] The specified overdrive current at the data input forces the data input to the opposite logic input state.
10. Dynamic characteristics
Table 7. Dynamic characteristics
Voltages are referenced to GND (ground = 0 V). For test circuit see Fig. 7.
Symbol Parameter Conditions
-40 °C to +85 °C
Min Typ[1] Max
tpd
propagation nAn to nYn; see Fig. 5
delay
VCC = 1.2 V
VCC = 1.65 V to 1.95 V
VCC = 2.3 V to 2.7 V
VCC = 2.7 V
VCC = 3.0 V to 3.6 V
ten
enable time nOE to nYn; see Fig. 6
VCC = 1.2 V
VCC = 1.65 V to 1.95 V
VCC = 2.3 V to 2.7 V
VCC = 2.7 V
VCC = 3.0 V to 3.6 V
tdis
disable time nOE to nYn; see Fig. 6
VCC = 1.2 V
VCC = 1.65 V to 1.95 V
VCC = 2.3 V to 2.7 V
VCC = 2.7 V
VCC = 3.0 V to 3.6 V
CPD
power
per input; VI = GND to VCC
dissipation
capacitance
VCC = 1.65 V to 1.95 V
VCC = 2.3 V to 2.7 V
VCC = 3.0 V to 3.6 V
[2]
-
1.5
1.0
1.0
1.1
[2]
-
1.5
1.0
1.0
1.0
[2]
-
2.5
1.0
1.0
1.8
[3]
-
-
-
11.0
-
4.8 10.7
2.6
5.3
2.6
4.7
2.2
4.1
15.0
-
6.2 12.1
3.5
6.4
3.3
5.8
2.8
4.6
10.0
-
4.4
8.7
2.4
4.9
3.2
6.2
3.1
5.2
4.8
-
8.3
-
11.4
-
-40 °C to +125 °C
Min
Max
-
-
1.5
11.3
1.0
5.9
1.0
6.0
1.1
5.5
-
-
1.5
12.7
1.0
7.1
1.0
7.5
1.0
6.0
-
-
2.5
9.4
1.0
5.3
1.0
8.0
1.8
6.5
-
-
-
-
-
-
[1] Typical values are measured at Tamb = 25 °C and VCC = 1.2 V, 1.8 V, 2.5 V, 2.7 V and 3.3 V respectively.
[2]
[3]
tpd is the same as tPLH and tPHL; ten is the same as tPZL and tPZH; tdis
CPD is used to determine the dynamic power dissipation (PD in μW).
is the same
PD = CPD x
VaCsCt2PLxZ
and tPHZ.
fi x N + ∑(CL
x
VCC2
x
fo)
where:
fi = input frequency in MHz; fo = output frequency in MHz; CL = output load capacitance in pF
VCC = supply voltage in Volts; N = number of inputs switching; ∑(CL x VCC2 x fo) = sum of the outputs.
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
pF
pF