Doc. No.: 14069241
Issued Date: Feb., 13, 2007
Model No.: M190A1-L07
Approval
2. ABSOLUTE MAXIMUM RATINGS
2.1 ABSOLUTE RATINGS OF ENVIRONMENT
Item
Symbol
Value
Min.
Max.
Unit
Note
Storage Temperature
TST
-20
+60
ºC
(1)
Operating Ambient Temperature
TOP
0
+50
Shock (Non-Operating)
SNOP
-
50
Vibration (Non-Operating)
VNOP
-
1.5
Note (1) Temperature and relative humidity range is shown in the figure below.
(a) 90 %RH Max. (Ta ≦ 40 ºC).
.tw (b) Wet-bulb temperature should be 39 ºC Max. (Ta > 40 ºC).
(c) No condensation.
Relative Humidity (%RH)
100
m 90
80
.co 60
Operating Range
40
d 20
lc10
Storage Range
ºC
(1), (2)
G
(3), (5)
G
(4), (5)
s -40
-20
0
20
40
60
80
Temperature (ºC)
.y Note (2) The temperature of panel display surface area should be 0 ºC Min. and 60 ºC Max.
Note (3) 11ms, half sine wave, 1 time for ± X, ± Y, ± Z.
w Note (4) 10 ~ 300 Hz, 10min/cycle, 3 cycles each X, Y, Z.
Note (5) At testing Vibration and Shock, the fixture in holding the module has to be hard and rigid enough
wso that the module would not be twisted or bent by the fixture.
wAt Room Temperature
LCD Module
Side Mount Fixing Screw
Side Mount Fixing Screw
Stage
Gap=2mm
Bracket
5 / 25