the positive terminal of the
battery cell BAT3 for cell-
balancing
bleeding function
under overcharge condition.
PIN12: VC2 -
Input pin for battery BAT3
voltage sensing. This pin is to be
connected to the positive
terminal of the battery cell BAT3.
PIN13: UD2 -
This pin is to be connected to the
positive terminal of the battery
cell BAT2 for cell-balancing
bleeding
function
under
n APPLICATION INFORMATIONS
THE OPERATION
Initialization
On initial power-up, such as connecting the
battery pack for the first time to the AIC1804, the
AIC1804 enters the power-down mode. A
charger must be applied to the AIC1804 circuit
to enable the pack.
Overcharge Protection
When the voltage of either of the battery cells
exceeds the overcharge protection voltage
(VOCP) beyond the overcharge delay time (TOC)
period, charging is inhibited by the turning-off of
the charge control MOSFET M2. The
overcharge delay time is set by the external
capacitor CTC. Inhibition of charging is
immediately released when the voltage of the
overcharged cell becomes lower than
overcharge release voltage (VOCR or VOCP-VHYS)
through discharging.
Overdischarge Protection
When the voltage of either of the battery cells
falls below the overdischarge protection voltage
(VODP) beyond the overdischarge delay time
(TOD) period, discharging is inhibited by the
turning-off of the discharge control MOSFET M1.
The overdischarge delay time is set by the
external capacitor CTD. Inhibition of discharging
AIC1804
overcharge condition.
PIN14: VC1 -
Input pin for battery BAT2
voltage sensing. This pin is to be
connected to the positive
terminal of the battery cell BAT2.
PIN15: UD1 - This pin is to be connected to the positive ter
PIN16: VCC -
Power supply pin and input for
battery BAT1 voltage sensing.
This pin is to be connected to the
positive terminal of the battery
cell BAT1.
is immediately released when the voltage of the
overdischarge cell becomes higher than the
overdischarge release voltage (VODR) through
charging.
Overcurrent Protection
In normal mode, the AIC1804 continuously
monitors the discharge current by sensing the
voltage of CS pin. If the voltage VCC-VCS
exceeds the overcurrent protection voltage (VOIP)
beyond the overcurrent delay time (TOI) period,
the overcurrent protection circuit operates and
discharging is inhibited by the turning-off of the
discharge control MOSFET M1. Discharging
must be inhibited for at least 256mS after
overcurrent takes place to avoid damage to
external control MOSFETs due to rapidly
switching transient between BATT+ and BATT-
terminals. The overcurrent condition returns to
normal mode when the load is released and the
impedance between the BATT+ and BATT-
terminals is 20Mor higher.
The AIC1804 is provided with the three
overcurrent detection levels (0.15V, 0.3V and
1.0V) and the three overcurrent delay time (TOI1,
TOI2 and TOI3) corresponding to each overcurrent
detection level. TOI1 is set by the external
capacitor CTI. TOI2 and TOI3 default to 4mS and
300µs respectively, and can not be adjusted due